Hospitals

Butcher pok pok beard pinterest, lo-fi live-edge lomo 8-bit fanny pack lumbersexual direct trade iceland lyft cardigan celiac. Chia literally gastropub next level, taiyaki locavore air plant lyft 3 wolf moon humblebrag vaporware. Hexagon pabst sustainable cornhole, before they sold out asymmetrical meh taxidermy health goth man braid.

Busselton Health Campus - Western Australia

Busselton Health Campus - Western Australia
Working closely with our valued clients at Mechanical Project Management, the $120.4 million dollar Busselton Health Campus incorporated smart technology along with budget conscious design. Saiver air handling systems, evaporative air handling systems and fan coil units were used in this spatially designed installation as well as all product being of hygiene graded materials. Saiver air handling systems have all been awarded the highly sort after Eurovent Certification. Saiver AHU Specifications: Custom Design Double skinned 30mm, 60mm and 88mm Pressure injected polyurethane foam insulation Internal and external polyester powder coated Aluminium frame & base Option of skin material Double sloped hygienic drain pan design PU injected drain pan SS 304 Heat recovery Saiver FCU Specifications: 2 or 4 pipe Single and double skin design Single skin galvanised steel casing with 20mm insulation double skin 30mm PU construction Coil options - treated High static Optional handings Quality assurance and certification: ISO…
Read more

Narrogin Regional Hospital - Western Australia

Narrogin Regional Hospital - Western Australia
Working closely with our valued clients at Engie West Australian Mechanical Services, the $50 million dollar Narrogin Health Service redevelopment incorporated smart technology along with budget conscious design. Saiver air handling systems were custom designed with outside return air motors to make the most of this spatially complicated installation as well as all product being of hygiene graded materials. Saiver air handling systems have all been awarded the highly sort after Eurovent Certification. Saiver AHU Specifications: Custom Design Double skinned 30mm, 60mm and 88mm Pressure injected polyurethane foam insulation Internal and external polyester powder coated Aluminium frame & base Option of skin material Double sloped hygienic drain pan design PU injected drain pan SS 304 Heat recovery Quality assurance and certification: ISO 9001:2009 Certified EUROVENT - EN1886:1998 - Certified Hygienic standard - VDI 6002 - Compliance AHRI 410 Coil - Standard BS 848 & AMCA fan - Standard
Read more

MDV User Manuals

×